Artificial intelligence is rapidly iterating, and the demand for computing power continues to grow. Data centers are facing higher capacity and power requirements, and they need to have higher energy efficiency while maintaining high availability and reliability. Bohao Data has partnered with Envicool to adopt Envision's efficient cooling and natural cooling solutions in multiple locations, achieving significant results in data center energy consumption control.


Taking Bohao Data Guangzhou No.6 Data Center as an example, the data center is located in Nansha District, Guangzhou City, with a building area of 49000 square meters. It is planned and constructed according to the national A-level standard, with a total IT power of about 35MW. The IT power of each single cabinet in the computer room is between 8-12KW, while maintaining a certain degree of scalability, with a maximum capacity of 24KW, providing support for computing power business. Since its launch in 2022, Bohao Data has actively explored and practiced low-carbon operation models for data centers, focusing on optimizing the energy consumption structure of data centers, adopting efficient and energy-saving equipment, and reducing unnecessary energy consumption from the source.


The data center adopts the Envicool XMint high-efficiency evaporative cooling composite multi split air conditioning solution, which utilizes Innovent's unique XFreeCooling high-efficiency variable frequency pneumatic heat pipe technology, liquid pump natural cooling technology, evaporative condensation technology, multi split adaptive refrigeration technology and other advanced refrigeration technologies. Combined with end of pipe air conditioning equipment, it can adaptively adjust according to outdoor working conditions, accurately control system pressure and temperature, and achieve high efficiency and energy saving during transitional seasons, effectively improving the annual energy efficiency ratio of the refrigeration system. It also adopts refrigerant leakage detection, redundant configuration and other methods to greatly enhance the reliability of the solution.


As a leading provider of customized data center construction and operation services in China, Bohao Data has not only focused on Guangdong Province, but also established data centers in first tier cities such as Beijing and Shanghai and their surrounding areas. At the same time, Bohao Data actively responds to the national "East Data West Computing" project, laying out data centers in the "East Data West Computing" node areas such as Chengdu, optimizing the national resource allocation, and building a national computing power network belonging to Bohao Data, better empowering customer business.


In the future, Bohao Data plans to deploy more Envicool XMint high-efficiency evaporative cooling composite multi unit air conditioning solutions in water rich areas, flexibly meeting the continuous cooling needs of data centers, effectively extending natural cooling time, and significantly reducing the energy consumption of data center cooling systems.


The Envicool XMint high-efficiency evaporative cooling composite multi split air conditioning solution has been selected for the "Low Carbon Technology Promotion Catalogue" in Guangdong Province and Shenzhen City, and has won multiple awards for data center technology achievements. It has the characteristics of efficient refrigeration, dispersed cooling sources, and flexible configuration, and has significant advantages in energy conservation such as water conservation, electricity conservation, and land conservation. It is particularly suitable for the scenario requirements of multi story and large-scale data center fluorine system solutions.


The person in charge of Bohao Data stated that adopting the efficient evaporative cooling composite multi split air conditioning solution from Envicool XMint can utilize the outdoor wet bulb temperature for a long time on the outdoor side, extending the duration of natural cooling application. For different demand scenarios, indoor side can be combined with room level precision air conditioning, inter row air conditioning, backboard air conditioning and other cold sources to achieve energy saving and consumption reduction, and reduce the PUE value of the data center.